توضیحات
Medium | Fluids |
Measurement | Switch, Continuous |
Design | Standard |
Probe type | Rod probe |
Probe length | 600 mm |
Process pressure | –1 bar … 10 bar |
Process temperature | –20 °C … +100 °C |
IO-Link | ✔ |
Accuracy of sensor element | ± 5 mm |
Reproducibility | ≤ 2 mm |
Resolution | < 2 mm |
Response time | < 400 ms |
Dielectricity constant | ≥ 5 for rod probe / cable probe
≥ 1.8 with coaxial tube |
Conductivity | No limitation |
Maximum level change | ≤ 500 mm/s |
Deactivated area at process connection | 25 mm |
Deactivated area at end of probe | ≥ 10 mm |
Supply voltage | 12 V DC … 30 V DC |
Power consumption | ≤ 100 mA at 24 V DC without output load |
Initialization time | ≤ 5 s |
Protection class | III |
Connection type | Round connector M12 x 1, 5-pin |
Output signal | 1 x PNP + 1 x PNP/NPN + 4 mA … 20 mA / 0 V … 10 V |
Hysteresis | Min. 2 mm, free adjustable |
Signal voltage HIGH | Vs – 2 V |
Signal voltage LOW | ≤ 2 V |
Output current | < 100 mA |
Inductive load | < 1 H |
Capacitive load | 100 nF |
Enclosure rating | IP67 |
Temperature drift | < 0.1 mm/K |
Lower signal level | 3.8 mA … 4 mA |
Upper signal level | 20 mA … 20.5 mA |
نقد و بررسیها